项目

四为满足不同类型数据中心的服务需求,项目示例:

Beijing Digital Economy Computing Power Center Project

Jiuxianqiao, Chaoyang District, Beijing Beijing Electronic Digital Intelligence Technology Co., Ltd.
As one of Beijing’s key “Three 100” projects, this center is positioned as the computing hub of the city’s “regional new-quality productivity center”. The total gross floor area is 35,765.81 m², with a building height of 24 m. The data center building has five floors, including 9,871 m² of certified data hall area, accommodating 3,100 racks and a certified IT capacity of 26,644 kW. The building’s functional zoning is clearly defined: the first floor houses the high-voltage cable termination room, ECC monitoring room, and other auxiliary spaces. The second to fifth floors on the north and south sides are primarily IT rooms, supported by transformer...
查看详情

Alibaba Ulanqab Data Center Project

Ulanqab City, Inner Mongolia Autonomous Region Alibaba
Under China’s national “Eastern Data, Western Computing” strategy, reliable intelligent-computing infrastructure has become a core pillar of digital-economy development. As a key node within the “Grassland Cloud Valley” cluster, this project plays a critical role in cross-regional compute scheduling and in supporting scientific research and innovation. Our testing scope covered the standalone NA132-D data center building. The building is a two-story facility with a site area of 5,974.74 m² and a total gross floor area of 23,629.43 m², with a building height of 18 m. It contains 8 data halls with approximately 1,196 IT racks. The design load is 12.3 kW per server rack and...
查看详情

China Telecom Shanghai Zhenru Data Center Project

6 Zhenda Road Campus, Putuo District, Shanghai China Telecom
As a core computing-power hub for the Yangtze River Delta’s digital transformation, this data center is located on the western side of the former Zhenru Radio Station site. The total site area is 71,948.4 m², and Building 3, with a site area of 14,750 m², serves as a flagship benchmark for green data centers in China. The project achieved a score of 82 to obtain LEED BD+C v4.1 Platinum certification, and has also passed multiple authoritative certifications including UPTIME Tier IV and CQC A-level. The power system adopts an architecture of three 35 kV utility feeders, dual diesel generators, and 2N redundant...
查看详情

DAYONE Data Center NTP Campus Project

Iskandar Puteri, Johor, Malaysia – GDS Nusajaya International Data Center Campus DAYONE (end clients include ByteDance, Alibaba, Kuaishou, etc.)
Designed for the hot, high-humidity climate of Southeast Asia, this multi-phase campus adopts modular construction and high-efficiency cooling technologies as its core strategy to build an overseas computing hub for multinational enterprises. Phases NTP-A through NTP-G have been launched in succession, with a planned total IT load of 192.5 MW and approximately 13,300 racks. Each phase adopts either a hybrid liquid + air cooling configuration or a pure air-cooling system, tailored to the load profile and application. For phases NTP-A, B, D, and G, the liquid-cooling solution increases heat-dissipation capability by up to 82% and reduces power consumption by about 15%, enabling stable PUE control under...
查看详情

Allinpay Fintech Jinqiao Data Center – Uptime M&O Certification Project

Jinqiao Economic & Technological Development Zone, Pudong New Area, Shanghai Allinpay Financial Technology Co., Ltd.
As a core data hub supporting financial transactions, payment clearing, and other mission-critical services, this data center is required to meet financial-grade standards for infrastructure continuity and stability. The focus of this project was to support the facility in achieving Uptime Institute Tier IV M&O (Management & Operations) certification, marking its operations capabilities as among the top internationally. The project scope covered the core data halls, power supply and distribution systems, and cooling systems. The data halls host approximately 800 high-density racks, each with a design power of 15–20 kW per cabinet, meeting the high compute demands of financial workloads. During...
查看详情

China Mobile Suzhou Cloud Capability Data Center – PUE Testing & Green Certification Project

Xiangcheng District, Suzhou, Jiangsu Province China Mobile
As China Mobile’s core East China node under the national “Eastern Data, Western Computing” strategy, this data center was built with a “zero-carbon computing power” target. This project covered two main tasks: full-load PUE testing and Green Data Center certification by the China Electronics Society, ultimately helping the site become a benchmark for green computing power in the Yangtze River Delta. The data center has a total construction area of approximately 120,000 m², with 2,500 standard racks and a designed total IT load of 20 MW. It adopts an integrated “wind–solar–storage–charging” green power system, including a 10 MW photovoltaic plant with an annual power generation of...
查看详情

中国移动苏州云能力数据中心 PUE 测试及绿色认证项目

江苏省苏州市相城区 中国移动
作为中国移动 “东数西算” 华东区域核心节点,该数据中心以 “零碳算力” 为建设目标,本次项目包含全负荷 PUE 测试与中国电子学会 “绿色数据中心” 认证两大核心任务,最终助力其成为长三角绿色算力标杆。 数据中心总建筑面积约 12 万㎡,部署 2500 个标准机柜,设计 IT 总负荷 20MW,采用 “风光储充” 一体化绿电供应体系(配套 10MW 光伏电站,年发电量超 1200 万度)。PUE 测试覆盖全年不同季节工况,通过对间接蒸发冷却系统、水蓄冷装置及余热回收系统的效能监测,最终实测 PUE 低至 1.12(全年平均),达到国内数据中心能效领先水平。 依托优异的能效表现与绿色技术应用,该数据中心顺利通过中国电子学会绿色数据中心(最高等级)认证,其冷电联供、智能能耗调度等技术方案,可每年减少碳排放约 8000 吨,为运营商级数据中心的低碳转型提供了技术参考,同时为长三角数字经济发展提供了清洁、高效的算力支撑。
查看详情

通联金融科技金桥数据中心 Uptime M&O 认证项目

上海市浦东新区金桥经济技术开发区 通联金融科技有限公司
作为支撑金融交易、支付清算等核心业务的数据枢纽,该数据中心对基础设施的连续性、稳定性要求达到金融级标准,本次项目核心为协助完成 Uptime Tier IV M&O(运维)认证,标志着其运维能力跻身国际顶尖水平。 项目覆盖数据中心核心机房区、供配电系统及制冷系统,其中机房区部署约 800 个高密度机柜,单机柜设计功率 15-20KW,满足金融业务高算力需求。认证检测过程中,重点验证了供电系统的 “2N+1” 冗余架构(双路 10KV 市电 + 柴油发电机 + UPS 冗余配置)、制冷系统的动态容错能力,以及故障场景下的 72 小时自持力,最终实现 99.999% 的可用性目标。 通过 Uptime M&O 认证后,该数据中心成为长三角地区少数具备金融级运维资质的数据枢纽,可有效保障跨银行支付、证券交易等关键业务的零中断运行,为金融科技领域基础设施运维提供了可复制的标准范式。
查看详情

DAYONE 数据中心 NTP 园区项目

马来西亚柔佛州依斯干达公主城,GDS 国际努沙再也数据中心园区 DAYONE(最终客户:字节、阿里、快手等)
面对东南亚高温高湿的严苛环境,该连续标段项目以模块化建设与高效制冷技术为核心,构建跨国企业的海外算力底座,已陆续开展 NTP-A 至 NTP-G 等多个标段,累计规划 IT 总负荷 192.5MW,机柜量 13300 个。 各标段针对性采用液冷 + 风冷复合冷却或纯风冷系统,其中 NTP-A、B、D、G 标段的液冷方案可将散热性能提升 82%,降低功耗 15%,在东南亚气候条件下实现 PUE 稳定控制。项目采用集装箱集成模式,配合预制化管网设计,实现短周期高效交付 —— 最快 4 个月完成单标段建设(如 NTP-E 标段)。 作为中国模块化数据中心出海的典型案例,其为字节、阿里等企业提供跨地域算力支撑,通过标准化检测与优化服务,保障连续标段的建设质量与运营可靠性,树立了海外数据中心绿色建设的标杆。
查看详情

中国电信上海真如数据中心项目

上海市普陀区真大路 6 号园区 中国电信
作为长三角数字化转型的核心算力底座,该数据中心坐落于原真如电台用地西端,总用地面积 71948.4 平方米,其中 3 号楼用地面积 14750 平方米,是国内绿色数据中心的标杆典范。 项目以 82 分高分斩获 LEED BD+C V4.1 铂金级认证,同时通过 UPTIME Tier 4、CQC-A 级等多项权威认证。供电系统采用三路 35kV 外市电 + 双柴发 + 2N 冗余 UPS 的架构,在保障 99.999% 可靠性的同时提升市电利用率。冷源供给方面,配备变频冷源自动控制系统,可根据季节动态调节冷量输出,显著优化 PUE 指标。 为降低环境影响,设施针对性配置室外冷塔降噪装置与管道烟气净化系统,实现绿色运行与周边环境的和谐共生。作为海纳数创中心的算力支撑核心,其为长三角数字创新资源共享提供了安全稳定的基础设施保障。
查看详情

阿里巴巴乌兰察布数据中心项目

内蒙古自治区乌兰察布市 阿里巴巴
在 “东数西算” 国家战略布局下,可靠的智算基础设施成为数字经济发展的核心支撑。该项目作为 “草原云谷” 的核心节点,承担着跨区域算力调度与科研创新支撑的关键使命,其测试范围覆盖 NA132-D 楼独栋数据中心机楼。 该建筑为二层结构,总用地面积 5974.74m²,总建筑面积 23629.43m²,建筑高度 18m,内设 8 个模块机房及约 1196 个机柜,其中 IT 机房整机柜设计功率 12.3KW,核心网络机柜设计功率 16.3KW。依托乌兰察布北纬 42 度的 “黄金纬度” 优势,每年近 10 个月可利用自然冷源,同等条件下节约能耗 20%-30%。 项目采用双电源供电架构,全面满足千卡并行智能计算需求,有效算力达行业领先的 92%,可拓展至万卡规模,为高校科研项目提供千亿参数大模型训练支撑。模块化机房设计不仅适配算力需求的动态增长,更通过绿电供应与自然冷却技术的结合,践行 “绿色智算” 发展理念。
查看详情

北京数字经济算力中心项目

北京市朝阳区酒仙桥 北京电子数智科技有限责任公司
作为北京市 “三个 100” 重点项目,该中心定位为 “区域新质生产力中心” 的算力枢纽,总建筑面积 35765.81㎡,建筑高度 24m,数据机房楼共五层,其中认证机房面积 9871㎡,部署 3100 个机柜,认证 IT 容量达 26644kW。 建筑功能分区明确:一层设高压电缆分界室、ECC 监控室等辅助空间,南北侧二至五层以 IT 机房为主,配套变配电室、电池室等设施,室外钢平台布置集装箱式柴油发电机组,柴发并机柜集中于一层。核心技术亮点在于融合三种冷却系统 ——AHU 间接蒸发冷却、多联热自然冷却及冷板芯片级冷却,结合 7000 余块光伏板(年发电量超 20 万度)与水源热泵余热回收技术,将 PUE 控制在 1.146 的行业领先水平。 通过数字孪生系统实现算力与能源调度协同,可提供 1000P 智能算力,为政府及中小企业提供 AI 全栈服务,成为京津冀算力互联网络的关键节点。
查看详情